- RF Module
- Communication Module
- Drone Detection
- Direction Finding Antenna
- Phased Array Radar
- Signal Jammer
- Signal Coverage
- GNSS System
- IMSI Catcher
- Optoelectronics System
5600‑5800MHz TDD 20W High‑Performance Linear Power Amplifier
This is a 5600‑5800MHz TDD 20W high‑performance linear power amplifier designed for 5.8GHz wireless communication systems, supporting uplink/downlink dual‑link and TX_EN/RX_EN transceiver switching control. Powered by 32V DC with operating current ≤5A, it provides downlink max output power 43±0.5dBm, gain 48±1.5dB; uplink gain 25±1.0dB, noise figure ≤3dB, in‑band spurious ≤‑36dBm, with excellent EVM and ACLR linearity indicators. Built‑in 0‑16dB numerical control attenuation, over‑temperature/over‑power/VSWR protection, supports RS485 real‑time monitoring and SWIM firmware upgrade. Equipped with SMA‑K/MCX‑K RF connectors, dimensions 165×160×33mm, operating temperature ‑10℃~+55℃, suitable for 5.8GHz TDD private network, base station RF amplification and wireless relay transmission applications.
TDD 5600-5800MHz 20W Linear Power Amplifier Technical Specifications
I. RF Indicator
|
Test Item |
Indicators |
Unit |
Remark |
||||||||||||
|
Downlink |
Uplink |
||||||||||||||
|
Frequency Range |
5600-5800 |
5600-5800 |
MHz |
||||||||||||
|
Maximum Output Power |
43±0.5 |
15 |
dBm |
||||||||||||
|
Gain |
48±1.5 |
25±1.0 |
dB |
||||||||||||
|
Noise Figure |
≤15 |
≤3 |
/ |
||||||||||||
Flatness |
≤3 |
≤2 |
dB |
||||||||||||
|
PA Voltage |
32 |
V |
32V |
||||||||||||
|
Power Conversion Efficiency |
>15% |
% |
@43dbm |
||||||||||||
|
Gain Adjustment Step Size |
1.0 |
Not supported |
dB |
||||||||||||
|
Numerical Control Regulation Error |
1-16dB |
≤1.0 |
Not supported |
dB |
|||||||||||
Spurious Emission |
In-Band |
≤-36 |
dBm |
Tested with CW signal at the center frequency and output power set to maximum |
|||||||||||
|
Out-of-Band |
9KHz-1GHz |
No Clutter Above Normal Noise Floor |
dBm |
||||||||||||
|
1G-12.75GHz |
dBm |
||||||||||||||
|
EVM |
≤10% |
≤1.2% |
Dynamic testing @43dbm |
||||||||||||
|
ACLR |
≤-35dBc |
||||||||||||||
|
Maximum Allowable Input Power |
≤+10dBm |
≤-10dBm |
dBm |
No damage occurs for continuous operation for 1 min |
|||||||||||
|
Input VSWR |
≤1.50 |
≤1.50 |
|||||||||||||
|
Output VSWR |
≤1.50 |
≤1.50 |
|||||||||||||
|
≤1.50 |
≤1.50 |
||||||||||||||
|
Switching Delay |
≤2us ≤4.8us |
||||||||||||||
|
High and Low Temperature Test |
Ambient Temperature (℃) |
-10~+55 |
℃ |
Starts normally at low temperatures, monitoring works normally |
|||||||||||
|
EVM |
≤15% |
≤1.2% |
@43dbm |
||||||||||||
|
Gain Stability |
±2 @-10℃~+55℃ |
dB |
|||||||||||||
|
Power Stability |
±1.5 @-10℃~+55℃ |
dB |
|||||||||||||
|
Current |
≤5A@32V |
A |
|||||||||||||
|
Power Interface |
KF2EDG5.08-4P |
Male Connector |
|||||||||||||
|
Monitoring Interface |
XH2.54-8P |
Male Connector |
|||||||||||||
|
RF Input/Output Connectors |
RF-IN/LAN OUT/ANT |
SMA-K/MCX-K |
|||||||||||||
|
Uplink/Downlink Switching Methods |
TX_EN and RX_EN signal |
10 indicates transmit state, 01 indicates receive 00: Power amplifier and receive are both off. Simultaneous setting to 11 is prohibited |
|||||||||||||
II. Monitoring Function (Implemented via Interface)
Monitoring Function |
Description |
Remark |
||||
Setting Parameters |
RF Signal Switch |
Turn the power amplifier on or off |
||||
|
Downlink Switch |
Turn the power amplifier on or off |
|||||
|
Downlink Attenuation Value ATT |
Numerical control attenuation, with a gain attenuation range of 0–16 dB and a step of 1 dB; |
Attenuation accuracy:1-20dB≤1.0; |
||||
|
PA Over-Temperature Shutdown Threshold |
The over-high temperature shutdown threshold of the power amplifier is configurable; the power amplifier will shut down automatically when its temperature exceeds this threshold. |
Generally setting 90℃ |
||||
|
Power Amplifier Over-power Shutdown |
The actual power value is 1dB higher than the downlink ALC start-up threshold, which will shut it down. |
|||||
|
Amplifier Fault Alarm |
When the enable switch is set to ON, the query module will generate a fault alarm. |
Reserved |
||||
Query Parameters |
Amplifier Switch Status |
If the amplifier is set to "off", the query should show the amplifier as off; otherwise, it should show the amplifier as on. |
||||
|
Downlink Output Power Level Value |
Detecting the output power value of the power amplifier, detection range(Pomax+2,Pomax-20) |
Detection accuracy: Pout±1dB |
||||
|
Downlink VSWR Value |
When connected to a mismatched load with a VSWR of 1.5 or 2.0, the queried value is ±0.2. |
The VSWR value is readable in real time |
||||
|
Temperature Query |
Detection module internal temperature, detection range: -40℃~+100℃ |
Detection error: ±3℃ |
||||
|
ALC Value Query |
The displayed value is equal to the actual set ALC value. |
|||||
|
ATT Value Query |
The displayed value is equal to the actual ATT value set. |
|||||
Alarm Parameters |
Over-Power Alarm |
An alarm will alarm when the maximum output power exceeds Pomax +1dBm, and will shut down when Pomax +2dBm. |
||||
|
Power Amplifier Over-Temperature Alarm |
When the internal temperature of the module exceeds the "amplifier over-temperature shutdown threshold", an over-temperature alarm will be displayed, and the amplifier will be shut down. The module can only resume operation when the temperature returns to below (amplifier over-temperature shutdown threshold -20℃). |
|||||
|
Amplifier Fault Alarm |
When the power amplifier tube is damaged, a power amplifier fault alarm will be displayed. |
This monitored quantity is reserved in the program, with configurable alarm enable/disable. |
||||
Module Communication Method |
Using RS-485 serial port |
|||||
Module Upgrade |
SWIM interface upgrade |
|||||
III. Appearance
External Dimensions |
165*160*33mm (Width * Length * Height, excluding interface dimensions) |
|
Interface Type |
2w2/2w4 |
|
Mounting Hole Diameter |
3.6mm |
|
Screw Installation and Fixing |
Screws are of the same specification, installed securely, and none are missing. |