Inquiry
Form loading...
TDD 200‑300MHz 20W RF Linear Power Amplifier
TDD

TDD 200‑300MHz 20W RF Linear Power Amplifier

This is a 200‑300MHz TDD 20W linear power amplifier powered by 32V, supporting uplink and downlink. Downlink max output 43±0.5dBm, gain 48±1.5dB; uplink gain 25±1.0dB, noise figure ≤3dB. It features numerical control attenuation, over-temperature/over-power/VSWR protection, RS485 monitoring and SWIM upgrade, operating at ‑10℃~+55℃, ideal for TDD private network communication and RF amplification systems.

    This is a 200‑300MHz TDD 20W linear power amplifier supporting uplink/downlink dual links and TX_EN/RX_EN intelligent switching. Powered by 32V DC with operating current ≤5A, it delivers downlink max output 43±0.5dBm, gain 48±1.5dB; uplink gain 25±1.0dB, noise figure ≤3dB, in‑band spurious ≤‑36dBm, with excellent EVM and ACLR performance. Integrated with 0‑16dB numerical control attenuation, over‑temperature/over‑power/VSWR protection, it supports RS485 real‑time monitoring and SWIM firmware upgrade. Operating at ‑10℃~+55℃ and sized 165×160×33mm, it is ideal for private network communication, TDD wireless systems and RF relay amplification.

    TDD 200-300MHz 20W Linear Power Amplifier Technical Specifications

    I. RF Indicator

    Test Item

    Indicators

    Unit

    Remark

    Downlink

    Uplink

    Frequency Range

    200-300

    200-300

    MHz

    Maximum Output Power

    43±0.5

    15

    dBm

    Gain

    48±1.5

    25±1.0

    dB

    Noise Figure

    ≤15

    ≤3

    /

    Flatness

    ≤3

    ≤2

    dB

    PA Voltage

    32

    V

    32V

    Power Conversion Efficiency

    >15%

    %

    @43dbm

    Gain Adjustment Step Size

    1.0

    Not supported

    dB

    Numerical Control Regulation Error

    1-16dB

    ≤1.0

    Not supported

    dB

    Spurious Emission

    In-Band

    ≤-36

    dBm

    Tested with CW signal at the center frequency and output power set to maximum

    Out-of-Band

    9KHz-1GHz

    No Clutter Above Normal Noise Floor

    dBm

    1G-12.75GHz

    dBm

    EVM

    ≤10%

    ≤1.2%

    Dynamic testing @43dbm

    ACLR

    ≤-35dBc

    Maximum Allowable Input Power

    ≤+10dBm

    ≤-10dBm

    dBm

    No damage occurs for continuous operation for 1 min

    Input VSWR

    ≤1.50

    ≤1.50

    Output VSWR

    ≤1.50

    ≤1.50

    ≤1.50

    ≤1.50

    Switching Delay

    ≤2us

    ≤4.8us

    High and Low Temperature Test

    Ambient Temperature (℃)

    -10~+55

    Starts normally at low temperatures, monitoring works normally

    EVM

    ≤15%

    ≤1.2%

    @43dbm

    Gain Stability

    ±2 @-10℃~+55℃

    dB

    Power Stability

    ±1.5 @-10℃~+55℃

    dB

    Current

    ≤5A@32V

    A

    Power Interface

    KF2EDG5.08-4P

    Male Connector

    Monitoring Interface

    XH2.54-8P

    Male Connector

    RF Input/Output Connectors

    RF-IN/LAN OUT/ANT

    SMA-K/MCX-K

    Uplink/Downlink Switching Methods

    TX_EN and RX_EN signal

    10 indicates transmit state, 01 indicates receive

    00: Power amplifier and receive are both off.

    Simultaneous setting to 11 is prohibited

    II. Monitoring Function (Implemented via Interface)

    Monitoring Function

    Description

    Remark

    Setting Parameters

    RF Signal Switch

    Turn the power amplifier on or off

    Downlink Switch

    Turn the power amplifier on or off

    Downlink Attenuation Value ATT

    Numerical control attenuation, with a gain attenuation range of 0–16 dB and a step of 1 dB;

    Attenuation accuracy:1-20dB≤1.0;

    PA Over-Temperature Shutdown Threshold

    The over-high temperature shutdown threshold of the power amplifier is configurable; the power amplifier will shut down automatically when its temperature exceeds this threshold.

    Generally setting 90℃

    Power Amplifier Over-power Shutdown

    The actual power value is 1dB higher than the downlink ALC start-up threshold, which will shut it down.

    Amplifier Fault Alarm

    When the enable switch is set to ON, the query module will generate a fault alarm.

    Reserved

    Query Parameters

    Amplifier Switch Status

    If the amplifier is set to "off", the query should show the amplifier as off; otherwise, it should show the amplifier as on.

    Downlink Output Power Level Value

    Detecting the output power value of the power amplifier, detection range(Pomax+2,Pomax-20)

    Detection accuracy: Pout±1dB

    Downlink VSWR Value

    When connected to a mismatched load with a VSWR of 1.5 or 2.0, the queried value is ±0.2.

    The VSWR value is readable in real time

    Temperature Query

    Detection module internal temperature, detection range: -40℃~+100℃

    Detection error: ±3℃

    ALC Value Query

    The displayed value is equal to the actual set ALC value.

    ATT Value Query

    The displayed value is equal to the actual ATT value set.

    Alarm Parameters

    Over-Power Alarm

    An alarm will alarm when the maximum output power exceeds Pomax +1dBm, and will shut down when Pomax +2dBm.

    Power Amplifier Over-Temperature Alarm

    When the internal temperature of the module exceeds the "amplifier over-temperature shutdown threshold", an over-temperature alarm will be displayed, and the amplifier will be shut down. The module can only resume operation when the temperature returns to below (amplifier over-temperature shutdown threshold -20℃).

    Amplifier Fault Alarm

    When the power amplifier tube is damaged, a power amplifier fault alarm will be displayed.

    This monitored quantity is reserved in the program, with configurable alarm enable/disable.

    Module Communication Method

    Using RS-485 serial port

    Module Upgrade

    SWIM interface upgrade

    III. Appearance

    External Dimensions

    165*160*33mm (Width * Length * Height, excluding interface dimensions)

    Interface Type

    2w2/2w4

    Mounting Hole Diameter

    3.6mm

    Screw Installation and Fixing

    Screws are of the same specification, installed securely, and none are missing.