700-6000MHz Ultra-Wideband 100W Dds Signal Generator Power Amplifier Module with Cooling Fan and Heat Sink for Uav Jammer
Parameter indicators
Item |
Parameter |
Unit |
Remarks |
|||
Operating Voltage |
28 |
V |
24-30V |
|||
Conversion efficiency |
≥42% |
% |
@100W typical |
|||
Controllable output power |
50W/100W/150W |
W |
Software set power level |
|||
ALC power adjustment range |
≥30 |
dB |
Voltage Controlled Attenuation |
|||
gain |
50±1.0 |
dB |
|
|||
In-band fluctuation |
≤2.5 |
dB |
peak-to-peak |
|||
spurious emission |
In working band |
≤-15dBm/1MHz |
dBm |
Measured when the center frequency plus CW signal to the maximum output power |
||
out of work band |
9KHz~1GHz |
No higher than normal noise floor clutter |
dBm |
|||
1G~12.75GHz |
dBm |
|||||
Maximum allowable input power |
≥+10dBm |
dBm |
Lasts 1min without damage |
|||
Input VSWR |
≤1.35 |
|
Add +28V, standard network output -10dBm |
|||
Output VSWR |
≤1.30 |
|
No power, standard network output -10dBm |
|||
≤1.35 |
|
Power On, Dual Directional Coupler Test |
||||
High and low temperature test |
Working ambient temperature (ºC) |
-10~+65 |
ºC |
Low temperature can start, monitoring works normally |
||
Gain Stability |
±1.5 @-40ºC~+65ºC |
dB |
|
|||
power stability |
±1 @-40ºC~+65ºC |
dB |
|
|||
Power Requirements |
≥8A @+28Vdc; |
|
CW output 100W |
|||
Power supply interface, monitoring interface RS485 |
7W2 |
|
Male |
|||
RF output connector |
N-F connector |
|||||
LCD liquid crystal display |
Display frequency, power, switch status |
|||||
with 3 LED lights |
POWER: Power indication; RUN: Running indication; ALARM: Alarm indication; |
|||||
Built-in cooling fan |
Modules can be run separately |
|||||
physical dimension |
255x165x80mm |
|||||
Weight |
3.5Kg |
|||||
Appearance (how to use) |
Black integrated module with fan (single or portable use) |
Module software settings
Monitoring |
Function Description |
Remarks |
|
Amplifier part setting parameters |
Amplifier switch |
Turn the amplifier on or off |
|
Alarm switch |
Enable and disable the alarm function |
|
|
Downlink Power Control |
The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set |
|
|
Amplifier over temperature alarm |
The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore |
|
|
Amplifier overpower alarm |
The actual power value is 2dB higher than the downlink ALC start control threshold and close |
|
|
Power amplifier standing wave alarm |
When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off |
|
|
Amplifier overcurrent alarm |
When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off |
|
|
Amplifier under-power alarm |
When the power amplifier detection power is less than 37dBm, an under-power alarm is displayed |
|
|
Amplifier overvoltage alarm |
When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down |
|
|
Amplifier part query parameters |
Amplifier switch status |
If the power amplifier is set to "OFF", the query should be the state of the power amplifier off; otherwise, the state of the power amplifier will be turned on. |
|
Downstream output power level value |
Detect power amplifier output power value, detection range (Pomax+2, Pomax-20) |
Detection accuracy:Pout±1dB |
|
Downward standing wave ratio |
The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0 |
|
|
temperature query |
Detect the internal temperature of the module, detection range: -40ºC~+100ºC |
detection error:±3ºC |
|
ALC value query |
The displayed value is equal to the actual set ALC value |
|
|
Voltage detection |
Detection module working voltage |
|
|
Current Detection |
Detection module operating current |
|
|
Signal generator settings |
Frequency setting mode 1 |
Any single frequency point setting within the range |
The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G |
Frequency setting mode 2 |
Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set |
||
Frequency setting mode 3 |
Set any 4 sub-frequency segments within the bandwidth, and a single sub-segment needs to be incremented |
||
module communication |
RS485 |
|
|
Interface definition |
+:28V,-: GND; control bit 1:485A,2:485B |