Leave Your Message
600-6200MHz Ultra-Wideband 100WDds Signal Generator Power Amplifier Module with Cooling Fan and Heat Sink for Uav Jammer

Products

600-6200MHz Ultra-Wideband 100WDds Signal Generator Power Amplifier Module with Cooling Fan and Heat Sink for Uav Jammer

600-6200MHz Ultra-Wideband 150W Dds Signal Generator Power Amplifier Module with Cooling Fan and Heat Sink for Uav Jammer

    Parameter indicators

    Item

    Parameter

    Unit

    Remarks

    Operating Voltage

    28

    V

    24-30V

    Conversion efficiency

    ≥42%

    %

    @100W typical

    Controllable output power

    50W/100W/150W

    W

    Software set power level

    ALC power adjustment range

    ≥30

    dB

    Voltage Controlled Attenuation

    gain

    50±1.0

    dB

     

    In-band fluctuation

    ≤2.5

    dB

    peak-to-peak

    spurious

    emission 

    In working band

    ≤-15dBm/1MHz

    dBm

    Measured when the center frequency plus CW signal to the maximum output power

    out of work band

    9KHz~1GHz

    No higher than normal noise floor clutter

    dBm

    1G~12.75GHz

    dBm

    Maximum allowable input power

    ≥+10dBm

    dBm

    Lasts 1min without damage

    Input VSWR

    ≤1.35

     

    Add +28V, standard network output -10dBm

    Output VSWR

    ≤1.30

     

    No power, standard network output -10dBm

    ≤1.35

     

    Power On, Dual Directional Coupler Test

    High and low temperature test

    Working ambient temperature (ºC)

    -10~+65

    ºC

    Low temperature can start, monitoring works normally

    Gain Stability

    ±1.5 @-40ºC~+65ºC

    dB

     

    power stability

    ±1 @-40ºC~+65ºC

    dB

     

    Power Requirements

    ≥8A @+28Vdc;

     

    CW output 100W

    Power supply interface, monitoring interface RS485

    7W2

     

    Male

    RF output connector

    N-F connector

    LCD liquid crystal display

    Display frequency, power, switch status

    with 3 LED lights

    POWER: Power indication; RUN: Running indication; ALARM: Alarm indication;

    Built-in cooling fan

    Modules can be run separately

    physical dimension

    355x180x90mm

    Weight

    6.5Kg

    Appearance (how to use)

    Black integrated module with fan (single or portable use)

    Module software settings

    Monitoring

    Function Description

    Remarks

    Amplifier part setting parameters

    Amplifier switch

    Turn the amplifier on or off

     

    Alarm switch

    Enable and disable the alarm function

     

    Downlink Power Control

    The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set

     

    Amplifier over temperature alarm

    The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore

     

    Amplifier overpower alarm

    The actual power value is 2dB higher than the downlink ALC start control threshold and close

     

    Power amplifier standing wave alarm

    When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off

     

    Amplifier overcurrent alarm

    When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off

     

    Amplifier under-power alarm

    When the power amplifier detection power is less than 37dBm, an under-power alarm is displayed

     

    Amplifier overvoltage alarm

    When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down

     

    Amplifier part query parameters

    Amplifier switch status

    If the power amplifier is set to "OFF", the query should be the state of the power amplifier off; otherwise, the state of the power amplifier will be turned on.

     

    Downstream output power level value

    Detect power amplifier output power value, detection range (Pomax+2, Pomax-20)

    Detection accuracy:Pout±1dB

    Downward standing wave ratio

    The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0

     

    temperature query

    Detect the internal temperature of the module, detection range: -40ºC~+100ºC

    detection error:±3ºC

    ALC value query

    The displayed value is equal to the actual set ALC value

     

    Voltage detection

    Detection module working voltage

     

    Current Detection

    Detection module operating current

     

    Signal generator settings

    Frequency setting mode 1

    Any single frequency point setting within the range

    The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G

    Frequency setting mode 2

    Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set

    Frequency setting mode 3

    Set any 4 sub-frequency segments within the bandwidth, and a single sub-segment needs to be incremented

    module communication

    RS485

     

    Interface definition

    +:28V,-: GND; control bit 1:485A,2:485B

     
    Indoor System Jammer 50m Shielding Distance Signal Blocker (11)82dCompany Profile (2)5fcCompany Profile (1)f5tIndoor System Jammer 50m Shielding Distance Signal Blocker (13)s5nIndoor System Jammer 50m Shielding Distance Signal Blocker (14)wqoIndoor System Jammer 50m Shielding Distance Signal Blocker (15)gceIndoor System Jammer 50m Shielding Distance Signal Blocker (16)ng6

    Leave Your Message